20742742
9781423549154
Out of Stock
The item you're looking for is currently unavailable.
The current study evaluated the feasibility of a 5-hour flight in MOPP4 with environmental conditions of l00 F and 50% relative humidity. Eight volunteer pilots participated in a within subject, repeated measures design. The test conditions included 70 F without nuclear, biological and chemical (NBC) gear (Cool Standard (CS)), 70 F with NBC gear (Cool MOPP (CM)), and 100 F with NBC gear and microclimate cooling (Hot MOPP (HM)). The test sessions consisted of an initial 20-minute warm up, two flight sorties and an intervening break (without NBC gear removal). Physiological parameters, flight performance, mood, and reaction time were measured during the test sessions. The peak mean core temperature did not exceed 99.8 F. Mean core temperature in the HM condition was about 0.4 F higher than CM and about 0.6 F higher than CS. The absolute increase was quite modest compared to the approved upper limit of l02.5 F. Mean percent dehydration was greatest for the HM condition despite the use of the cooling vest. However, the fluid deficit of approximately 300 cc per hour was a totally compensable rate. The results indicated that the cooling vest was effective in preventing heat stress during an extended rotary-wing mission in a hot, humid condition.Army Aeromedical Research Lab Fort Rucker Al is the author of 'Heat Stress Evaluation of Air Warrior Block I MOPP0 and MOPP4 Ensembles With and Without Microclimate Cooling' with ISBN 9781423549154 and ISBN 1423549155.